{"id":28502,"date":"2025-08-20T13:36:21","date_gmt":"2025-08-20T13:36:21","guid":{"rendered":"https:\/\/protasoftware.com\/?p=28502"},"modified":"2026-06-19T12:38:01","modified_gmt":"2026-06-19T12:38:01","slug":"assessment-pbd-to-eurocode-8-part-3-3","status":"publish","type":"wiki","link":"https:\/\/protasoftware.com\/wiki\/assessment-pbd-to-eurocode-8-part-3-3\/","title":{"rendered":"Assessment &amp; PBD to Eurocode 8 Part 3"},"content":{"rendered":"<h3 data-start=\"191\" data-end=\"206\">Introduction<\/h3>\n<p>This design guide <strong>provides a detailed overview<\/strong> of how to assess the seismic performance of existing structures in accordance with <strong>Eurocode 8 Part 3 (EN 1998-3:2005)<\/strong> and Eurocode 8 Part 1 (EN 1998-1:2004). <strong>ProtaStructure software, moreover<\/strong>, offers a <strong>comprehensive workflow<\/strong> for the seismic assessment of reinforced concrete buildings, supporting both the strengthening of undamaged buildings and the repair of earthquake-damaged structures, while ensuring compliance with Eurocode principles. Thus, the software <strong>enables engineers to perform performance-based assessments<\/strong>, select intervention strategies, and generate comprehensive evaluation reports. This <strong>Eurocode 8 Assessment Framework<\/strong> ensures that both seismic input and assessment logic fully comply with Eurocode methodology, providing a robust foundation for structural evaluations.<\/p>\n<p><strong>Eurocode 8 Assessment Framework<\/strong> the <strong>Eurocode 8 Assessment Framework<\/strong> defines performance requirements at <strong>three main Performance Limit States (LS)<\/strong>, <strong>basing them on structural damage levels<\/strong>:<\/p>\n<h3><strong>Near Collapse (NC)<\/strong><\/h3>\n<p>The structure sustains severe damage, yet exhibits minimal residual lateral strength and stiffness. Although vertical elements may still support gravity loads, most non-structural components collapse, and significant permanent drifts occur. Engineers deem it unlikely for the structure to survive another seismic event and consider the structure on the verge of collapse. This state corresponds to a return period of 2475 years for ordinary buildings.<\/p>\n<h3><strong>Significant Damage (SD)<\/strong><\/h3>\n<p>The structure experiences notable damage with some remaining lateral strength and stiffness. Vertical elements continue to carry loads, and non-structural components such as infills and partitions are damaged but generally remain in place. Moderate permanent drifts occur, and repair <strong>may be uneconomical<\/strong>. For ordinary buildings, this state <strong>is associated with<\/strong> a 475-year return period.<\/p>\n<h3><strong>Damage Limitation (DL)<\/strong><\/h3>\n<p>The structure incurs only minor damage. Structural components do not yield significantly and retain most of their strength and stiffness. Non-structural elements may develop widespread cracking, but engineers <strong>can repair<\/strong> the damage, and permanent drifts <strong>remain negligible<\/strong>. The structure remains functional without requiring intervention. This state corresponds to a return period of 225 years for ordinary buildings.<\/p>\n<p><strong>Knowledge Levels and Confidence Factors<\/strong> the <strong>Eurocode 8 Assessment Framework<\/strong> defines <strong>three Knowledge Levels (KL)<\/strong> for selecting analysis types and confidence factor values:<\/p>\n<h3><strong>KL1 \u2013 Limited Knowledge (EC8-Part 3, Clause 3.3.2)<\/strong><\/h3>\n<p>Users <strong>partially know<\/strong> the geometry; detailing <strong>is unavailable<\/strong>; and <strong>they assume default material properties<\/strong>. Users <strong>must only use<\/strong> linear analysis methods.<\/p>\n<h3><strong>KL2 \u2013 Normal Knowledge <\/strong><strong>(EC8-Part 3, Clause 3.3.3)<\/strong><\/h3>\n<p>Engineers <strong>know<\/strong> the overall geometry and member sizes from an extended site survey or outline construction drawings. They <strong>know<\/strong> the mechanical properties of materials either through extended in-situ testing or from original design specifications. This level permits both linear and nonlinear analyses.<\/p>\n<h3><strong>KL3 \u2013 Full Knowledge <\/strong><strong>(EC8-Part 3, Clause 3.3.4)<\/strong><\/h3>\n<p>This <strong>represents<\/strong> the highest knowledge level, where engineers <strong>comprehensively know<\/strong> the overall structural geometry, member sizes, detailing, and material properties from a comprehensive site survey, complete drawings, or original test reports. This level allows nonlinear analysis methods with the lowest confidence factor. Engineers <strong>apply corresponding Confidence Factors (CF)<\/strong> to capacity calculations: 1.35 for KL1, 1.20 for KL2, and 1.00 for KL3. ProtaStructure <strong>allows<\/strong> users to determine the knowledge level and assign the confidence factor accordingly.<\/p>\n<p><strong>Structural Analysis Methods<\/strong> ProtaStructure <strong>supports various structural analysis methods<\/strong> for assessing existing buildings in accordance with EN 1998-3:2005:<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/protasoftware.com\/wp-content\/uploads\/2025\/08\/Eurocode-8-Assessment-Framework_3-1024x598.png\" alt=\"Eurocode 8 Assessment Framework\" width=\"640\" height=\"374\" \/><\/p>\n<h3><strong>Lateral Force Analysis (Linear)<\/strong><\/h3>\n<p>Engineers use this method when the fundamental mode of vibration <strong>predominantly governs<\/strong> the structural response. The method distributes seismic actions as lateral forces along the height of the building.<\/p>\n<h3><strong>Multi-Modal Response Spectrum Analysis (Linear)<\/strong><\/h3>\n<p>This method determines the seismic response of the structure by superimposing the contributions of multiple vibration modes using the elastic response spectrum. Consequently, this method <strong>provides a more accurate representation<\/strong> of structural behavior for irregular, tall, or torsionally sensitive buildings compared to single-mode methods.<\/p>\n<h3><strong>Nonlinear Static Analysis (Pushover)<\/strong><\/h3>\n<p>This method <strong>evaluates<\/strong> the nonlinear behavior of a structure under seismic loading. It <strong>also provides<\/strong> crucial information such as the capacity curve, plastic hinge development, and collapse mechanism.<\/p>\n<h3><strong>Nonlinear Time History Dynamic Analysis<\/strong><\/h3>\n<p>This method <strong>computes<\/strong> the nonlinear dynamic response of structures under seismic effects by directly integrating the differential equations of motion over time. Thus, it <strong>allows<\/strong> direct modeling of energy dissipation, loading\/unloading cycles, and damage accumulation at the element level.<\/p>\n<h3><strong>q-Factor Approach<\/strong><\/h3>\n<p>This approach <strong>accounts for<\/strong> nonlinear seismic behavior indirectly, by reducing elastic analysis results using a behavior factor (q). This factor <strong>represents<\/strong> the expected ductility level and energy dissipation capacity of the structure. Furthermore, this method <strong>is suitable<\/strong> for preliminary assessments because it does not directly capture local failures or plastic hinge formation.<\/p>\n<p><strong>Key Assessment Checks<\/strong> The software <strong>performs detailed checks<\/strong> on structural elements:<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/protasoftware.com\/wp-content\/uploads\/2025\/08\/Eurocode-8-Assessment-Framework_2-e1755696140737-1024x548.png\" alt=\"\" width=\"640\" height=\"343\" \/><\/p>\n<h3><strong>Shear Capacity Check<\/strong><\/h3>\n<p>This check is <strong>mandatory<\/strong> for beams, columns, and walls for all performance levels (NC, SD, DL). Engineers <strong>classify<\/strong> elements as <strong>ductile<\/strong> if VEd \u2264 VR (shear demand \u2264 shear capacity) and <strong>brittle<\/strong> if VEd &gt; VR. Brittle elements <strong>fail<\/strong> prior to flexural yielding, and engineers <strong>must retrofit them<\/strong> or <strong>exclude them<\/strong> from nonlinear deformation checks.<\/p>\n<h3><strong>Beam Chord Rotation Check (Flexure)<\/strong><\/h3>\n<p>This check verifies that the beam chord rotation demand (\u03b8Ed) from seismic analysis remains within the element&#8217;s ultimate rotation capacity (\u03b8um), particularly at the Near Collapse (NC) level. Eurocode 8 <strong>makes specific adjustments<\/strong> for lack of earthquake detailing, lap-spliced deformed bars, and smooth bars with hooks.<\/p>\n<h3><strong>Beam-Column Joint Verification<\/strong><\/h3>\n<p>This check <strong>assesses<\/strong> the shear safety of beam-column joints by comparing the design shear demand (Vj,Ed) with the shear capacity (Vj,Rd).<\/p>\n<p><strong data-start=\"0\" data-end=\"49\" data-is-only-node=\"\">Application and Reporting in ProtaStructure <\/strong>the software facilitates Eurocode 8 Part 3 assessment through the following capabilities.<\/p>\n<h3><strong>Defining Existing Reinforcement<\/strong><\/h3>\n<p>Users <strong>can do this<\/strong> by entering detailed reinforcement from plans or by defining approximate reinforcement ratios, with member-based approaches taking priority.<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/protasoftware.com\/wp-content\/uploads\/2025\/08\/Eurocode-8-Assessment-Framework_1-e1755696106847-1024x397.png\" alt=\"\" width=\"640\" height=\"248\" \/><\/p>\n<h3><strong>Specifying Seismic Parameters<\/strong><\/h3>\n<p>This includes response spectrum parameters, design spectral acceleration, and site class.<\/p>\n<h3><strong>Selecting Analysis Methods and Limit States<\/strong><\/h3>\n<p>Users <strong>achieve this<\/strong> through an intuitive &#8220;Assessment Wizard&#8221;.<\/p>\n<h3><strong>Generating Comprehensive Reports<\/strong><\/h3>\n<p>After analysis, ProtaStructure <strong>generates<\/strong> detailed results screens and reports summarizing assessment parameters, element performance by limit state, ductility classification, joint shear checks, and member-level shear and beam chord rotation checks. Consequently, these reports clearly <strong>highlight<\/strong> members that fail checks or that ProtaStructure <strong>classifies<\/strong> as brittle, indicating potential retrofitting needs.<\/p>\n<p>In conclusion, the software&#8217;s integrated approach <strong>ensures<\/strong> robust and effective structural evaluations fully compliant with the <strong>Eurocode 8 Assessment Framework<\/strong>.<\/p>\n<h3>Additional Resources<\/h3>\n<p>For additional guidance or technical support, please contact Prota Software Inc. In addition, you can find more resources and practical examples on the Prota Software <a href=\"https:\/\/protasoftware.com\/community\/\">Community Page<\/a>. This page includes <a href=\"https:\/\/protasoftware.com\/community\/webinar-recordings\/\">Webinar Recordings<\/a>, a <a href=\"https:\/\/protasoftware.com\/community\/projects-gallery\/\">Project Gallery<\/a>, and our <a href=\"https:\/\/www.youtube.com\/@ProtaStructure\" target=\"_new\" rel=\"noopener\">YouTube Channel<\/a>.<\/p>\n<p>\t\t\t<a href=\"https:\/\/protasoftware.com\/wp-content\/uploads\/2025\/08\/ProtaStructure-Design-Guide-Assessment-to-Eurocode-8-Part-3.pdf\" target=\"_blank\"><br \/>\n    Open Document<br \/>\n<\/a><\/p>\n","protected":false},"excerpt":{"rendered":"<p>Introduction This design guide provides a detailed overview of how to assess the seismic performance of existing structures in accordance with Eurocode 8 Part 3&hellip;<\/p>\n","protected":false},"author":1,"featured_media":0,"parent":0,"menu_order":0,"template":"","meta":{"_whitepaper_youtube_videos":"","_whitepaper_youtube_url":"","_whitepaper_youtube_thumbnail":"","footnotes":""},"categories":[156,6],"whitepaper_topic":[],"whitepaper_product":[],"whitepaper_type":[],"class_list":["post-28502","wiki","type-wiki","status-publish","hentry","category-seismic-capabilities","category-technical-manuals"],"yoast_head":"<!-- This site is optimized with the Yoast SEO Premium plugin v27.9 (Yoast SEO v27.9) - https:\/\/yoast.com\/product\/yoast-seo-premium-wordpress\/ -->\n<title>Assessment &amp; PBD to Eurocode 8 Part 3<\/title>\n<meta name=\"description\" content=\"Eurocode 8 Assessment Framework explained: key limit states, knowledge levels, and methods for seismic building evaluation.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/protasoftware.com\/wiki\/assessment-pbd-to-eurocode-8-part-3-3\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Prota Software\" \/>\n<meta property=\"og:description\" content=\"Eurocode 8 Assessment Framework explained: key limit states, knowledge levels, and methods for seismic building evaluation.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/protasoftware.com\/wiki\/assessment-pbd-to-eurocode-8-part-3-3\/\" \/>\n<meta property=\"og:site_name\" content=\"Prota Software\" \/>\n<meta property=\"article:modified_time\" content=\"2026-06-19T12:38:01+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/protasoftware.com\/wp-content\/uploads\/2025\/08\/Eurocode-8-Assessment-Framework_3-1024x598.png\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:title\" content=\"Prota Software\" \/>\n<meta name=\"twitter:label1\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data1\" content=\"6 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/protasoftware.com\\\/wiki\\\/assessment-pbd-to-eurocode-8-part-3-3\\\/\",\"url\":\"https:\\\/\\\/protasoftware.com\\\/wiki\\\/assessment-pbd-to-eurocode-8-part-3-3\\\/\",\"name\":\"Assessment & PBD to Eurocode 8 Part 3\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/protasoftware.com\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/protasoftware.com\\\/wiki\\\/assessment-pbd-to-eurocode-8-part-3-3\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/protasoftware.com\\\/wiki\\\/assessment-pbd-to-eurocode-8-part-3-3\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/protasoftware.com\\\/wp-content\\\/uploads\\\/2025\\\/08\\\/Eurocode-8-Assessment-Framework_3-1024x598.png\",\"datePublished\":\"2025-08-20T13:36:21+00:00\",\"dateModified\":\"2026-06-19T12:38:01+00:00\",\"description\":\"Eurocode 8 Assessment Framework explained: key limit states, knowledge levels, and methods for seismic building evaluation.\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/protasoftware.com\\\/wiki\\\/assessment-pbd-to-eurocode-8-part-3-3\\\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/protasoftware.com\\\/wiki\\\/assessment-pbd-to-eurocode-8-part-3-3\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/protasoftware.com\\\/wiki\\\/assessment-pbd-to-eurocode-8-part-3-3\\\/#primaryimage\",\"url\":\"https:\\\/\\\/protasoftware.com\\\/wp-content\\\/uploads\\\/2025\\\/08\\\/Eurocode-8-Assessment-Framework_3-1024x598.png\",\"contentUrl\":\"https:\\\/\\\/protasoftware.com\\\/wp-content\\\/uploads\\\/2025\\\/08\\\/Eurocode-8-Assessment-Framework_3-1024x598.png\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/protasoftware.com\\\/wiki\\\/assessment-pbd-to-eurocode-8-part-3-3\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/protasoftware.com\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Wiki\",\"item\":\"https:\\\/\\\/protasoftware.com\\\/wiki\\\/\"},{\"@type\":\"ListItem\",\"position\":3,\"name\":\"Assessment &amp; PBD to Eurocode 8 Part 3\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/protasoftware.com\\\/#website\",\"url\":\"https:\\\/\\\/protasoftware.com\\\/\",\"name\":\"Prota Software\",\"description\":\"\",\"publisher\":{\"@id\":\"https:\\\/\\\/protasoftware.com\\\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/protasoftware.com\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/protasoftware.com\\\/#organization\",\"name\":\"Prota Software\",\"url\":\"https:\\\/\\\/protasoftware.com\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/protasoftware.com\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/protasoftware.com\\\/wp-content\\\/uploads\\\/2026\\\/07\\\/prota-logo.png\",\"contentUrl\":\"https:\\\/\\\/protasoftware.com\\\/wp-content\\\/uploads\\\/2026\\\/07\\\/prota-logo.png\",\"width\":1200,\"height\":340,\"caption\":\"Prota Software\"},\"image\":{\"@id\":\"https:\\\/\\\/protasoftware.com\\\/#\\\/schema\\\/logo\\\/image\\\/\"}}]}<\/script>\n<!-- \/ Yoast SEO Premium plugin. -->","yoast_head_json":{"title":"Assessment & PBD to Eurocode 8 Part 3","description":"Eurocode 8 Assessment Framework explained: key limit states, knowledge levels, and methods for seismic building evaluation.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/protasoftware.com\/wiki\/assessment-pbd-to-eurocode-8-part-3-3\/","og_locale":"en_US","og_type":"article","og_title":"Prota Software","og_description":"Eurocode 8 Assessment Framework explained: key limit states, knowledge levels, and methods for seismic building evaluation.","og_url":"https:\/\/protasoftware.com\/wiki\/assessment-pbd-to-eurocode-8-part-3-3\/","og_site_name":"Prota Software","article_modified_time":"2026-06-19T12:38:01+00:00","og_image":[{"url":"https:\/\/protasoftware.com\/wp-content\/uploads\/2025\/08\/Eurocode-8-Assessment-Framework_3-1024x598.png","type":"","width":"","height":""}],"twitter_card":"summary_large_image","twitter_title":"Prota Software","twitter_misc":{"Est. reading time":"6 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/protasoftware.com\/wiki\/assessment-pbd-to-eurocode-8-part-3-3\/","url":"https:\/\/protasoftware.com\/wiki\/assessment-pbd-to-eurocode-8-part-3-3\/","name":"Assessment & PBD to Eurocode 8 Part 3","isPartOf":{"@id":"https:\/\/protasoftware.com\/#website"},"primaryImageOfPage":{"@id":"https:\/\/protasoftware.com\/wiki\/assessment-pbd-to-eurocode-8-part-3-3\/#primaryimage"},"image":{"@id":"https:\/\/protasoftware.com\/wiki\/assessment-pbd-to-eurocode-8-part-3-3\/#primaryimage"},"thumbnailUrl":"https:\/\/protasoftware.com\/wp-content\/uploads\/2025\/08\/Eurocode-8-Assessment-Framework_3-1024x598.png","datePublished":"2025-08-20T13:36:21+00:00","dateModified":"2026-06-19T12:38:01+00:00","description":"Eurocode 8 Assessment Framework explained: key limit states, knowledge levels, and methods for seismic building evaluation.","breadcrumb":{"@id":"https:\/\/protasoftware.com\/wiki\/assessment-pbd-to-eurocode-8-part-3-3\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/protasoftware.com\/wiki\/assessment-pbd-to-eurocode-8-part-3-3\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/protasoftware.com\/wiki\/assessment-pbd-to-eurocode-8-part-3-3\/#primaryimage","url":"https:\/\/protasoftware.com\/wp-content\/uploads\/2025\/08\/Eurocode-8-Assessment-Framework_3-1024x598.png","contentUrl":"https:\/\/protasoftware.com\/wp-content\/uploads\/2025\/08\/Eurocode-8-Assessment-Framework_3-1024x598.png"},{"@type":"BreadcrumbList","@id":"https:\/\/protasoftware.com\/wiki\/assessment-pbd-to-eurocode-8-part-3-3\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/protasoftware.com\/"},{"@type":"ListItem","position":2,"name":"Wiki","item":"https:\/\/protasoftware.com\/wiki\/"},{"@type":"ListItem","position":3,"name":"Assessment &amp; PBD to Eurocode 8 Part 3"}]},{"@type":"WebSite","@id":"https:\/\/protasoftware.com\/#website","url":"https:\/\/protasoftware.com\/","name":"Prota Software","description":"","publisher":{"@id":"https:\/\/protasoftware.com\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/protasoftware.com\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Organization","@id":"https:\/\/protasoftware.com\/#organization","name":"Prota Software","url":"https:\/\/protasoftware.com\/","logo":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/protasoftware.com\/#\/schema\/logo\/image\/","url":"https:\/\/protasoftware.com\/wp-content\/uploads\/2026\/07\/prota-logo.png","contentUrl":"https:\/\/protasoftware.com\/wp-content\/uploads\/2026\/07\/prota-logo.png","width":1200,"height":340,"caption":"Prota Software"},"image":{"@id":"https:\/\/protasoftware.com\/#\/schema\/logo\/image\/"}}]}},"_links":{"self":[{"href":"https:\/\/protasoftware.com\/wp-json\/wp\/v2\/wiki\/28502","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/protasoftware.com\/wp-json\/wp\/v2\/wiki"}],"about":[{"href":"https:\/\/protasoftware.com\/wp-json\/wp\/v2\/types\/wiki"}],"author":[{"embeddable":true,"href":"https:\/\/protasoftware.com\/wp-json\/wp\/v2\/users\/1"}],"version-history":[{"count":1,"href":"https:\/\/protasoftware.com\/wp-json\/wp\/v2\/wiki\/28502\/revisions"}],"predecessor-version":[{"id":36063,"href":"https:\/\/protasoftware.com\/wp-json\/wp\/v2\/wiki\/28502\/revisions\/36063"}],"wp:attachment":[{"href":"https:\/\/protasoftware.com\/wp-json\/wp\/v2\/media?parent=28502"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/protasoftware.com\/wp-json\/wp\/v2\/categories?post=28502"},{"taxonomy":"whitepaper_topic","embeddable":true,"href":"https:\/\/protasoftware.com\/wp-json\/wp\/v2\/whitepaper_topic?post=28502"},{"taxonomy":"whitepaper_product","embeddable":true,"href":"https:\/\/protasoftware.com\/wp-json\/wp\/v2\/whitepaper_product?post=28502"},{"taxonomy":"whitepaper_type","embeddable":true,"href":"https:\/\/protasoftware.com\/wp-json\/wp\/v2\/whitepaper_type?post=28502"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}