{"id":32973,"date":"2026-04-27T12:34:26","date_gmt":"2026-04-27T12:34:26","guid":{"rendered":"https:\/\/protasoftware.com\/technical-manuals\/fe-analysis-of-foundations\/punching-shear-check-for-raft-foundation\/"},"modified":"2026-06-19T12:37:50","modified_gmt":"2026-06-19T12:37:50","slug":"punching-shear-check-for-raft-foundation","status":"publish","type":"wiki","link":"https:\/\/protasoftware.com\/wiki\/punching-shear-check-for-raft-foundation\/","title":{"rendered":"Punching Shear Check For Raft Foundation"},"content":{"rendered":"<h2 id=\"Raft_Foundation_Punching_Shear_Check_Scope__Limitation\" class=\"toc_anchors\"><span class=\"colour\">Raft Foundation Punching Shear Check Scope &amp; Limitation<\/span><\/h2>\n<div><span><span class=\"colour\">The scope of the punching shear check for raft foundation are :&nbsp;<\/span><\/span><\/div>\n<div>\n<ol>\n<li style=\"list-style-type: decimal\"><span class=\"colour\">Punching shear check can be performed for columns and discrete walls supported on raft foundation.<\/span><span class=\"colour\"><br \/><\/span><\/li>\n<li style=\"list-style-type: decimal\"><span class=\"colour\">Punching shear check cannot performed for merged core walls supported on raft foundation, as the shear perimeter is irregular.&nbsp;<\/span><\/li>\n<li style=\"list-style-type: decimal\"><span class=\"size\" style=\"font-size: 16px\"><span class=\"colour\">Punching shear check cannot be performed for piled raft foundation, as shear perimeter is complex &amp; influenced by irregular piles location.&nbsp;<\/span><\/span><\/li>\n<\/ol>\n<div>\n<div><span class=\"KB_New_Editor_Highlights\" style=\"margin: 10px 0px;position: relative;padding: 10px 10px 10px 40px\"><img decoding=\"async\" alt=\"Idea\" data-image=\"contentStyle\" style=\"position: absolute;left: 12px;top: 14px;width: 15px;max-width: 100%\" data-type=\"non-resize\" src=\"https:\/\/protasoftware.com\/wp-content\/uploads\/2026\/04\/prota-doc-b8b1551b50420d6db33946497198f0fc.png\"><\/p>\n<div><span class=\"colour\">Please ensure that FE Raft Foundation Analysis must be completed before performing punching shear check, i.e. the checking cannot be performed in the absence of soil stress data<\/span>.&nbsp;<\/div>\n<div>Refer to this article :&nbsp;<a href=\"https:\/\/support.protasoftware.com\/portal\/en\/kb\/articles\/raft-foundation-and-piled-raft-foundation-analysis-design-example#Raft_Foundation_Example\" target=\"_blank\" rel=\"noopener noreferrer\">Raft Foundation and Piled Raft Foundation Analysis &amp; Design Example<\/a><\/div>\n<p><\/span><\/div>\n<\/div>\n<\/div>\n<h2 id=\"Punching_Shear_Check_Procedure\" class=\"toc_anchors\"><span class=\"colour\">Punching Shear Check Procedure<\/span><\/h2>\n<div><span class=\"size\" style=\"font-size: 16px\"><span class=\"colour\">Please follow steps below to perform punching shear check in foundation level:<\/span><\/span><\/div>\n<ol>\n<li style=\"list-style-type: decimal\">\n<div><span class=\"size\" style=\"font-size: 16px\"><span class=\"colour\">In Storey 0, select\/ multiple select the columns.<\/span><\/span><span class=\"colour\"> <\/span><span class=\"size\" style=\"font-size: 16px\"><span class=\"colour\"><br \/><\/span><\/span><\/div>\n<\/li>\n<li style=\"list-style-type: decimal\">\n<div><span class=\"size\" style=\"font-size: 16px\"><span class=\"colour\">Click&nbsp;<\/span><\/span><span class=\"colour\"> <\/span><i><b><span class=\"size\" style=\"font-size: 16px\"><span class=\"colour\">Column Punching Check<\/span><\/span><\/b><\/i><span class=\"colour\"> <\/span><span class=\"size\" style=\"font-size: 16px\"><span class=\"colour\">&nbsp;under the <\/span><\/span><span class=\"colour\"> <\/span><b><span class=\"size\" style=\"font-size: 16px\"><span class=\"colour\">Column<\/span><\/span><\/b><span class=\"colour\"> <\/span><span class=\"size\" style=\"font-size: 16px\"><span class=\"colour\"> tab<\/span><br \/><img decoding=\"async\" data-zdeskdocselectedclass=\"best\" data-zdeskdocid=\"img_2990628490968439\" class=\"docsimage\" style=\"padding: 0px;max-width: 100%;width: 654px;height: auto\" src=\"https:\/\/desk.zoho.com\/DocsDisplay?zgId=672206093&amp;mode=inline&amp;blockId=47oexd60788fc88a2441f80effbe9fc767d1c\"><\/span><\/div>\n<\/li>\n<li style=\"list-style-type: decimal\"><span class=\"colour\">The punching check for raft foundation dialog is similar to the punching check for wall and columns, the only difference is there are an extra column &quot;Soil Pressure&quot; and an input field for the value of &quot;Tributary Area of Column Ave Soil Pressure&quot; in punching check for raft foundation dialog.&nbsp;<\/span><br \/><img decoding=\"async\" src=\"https:\/\/protasoftware.com\/wp-content\/uploads\/2026\/04\/prota-doc-880411f4a13f4a9bdb2d26f5e152d645.png\" style=\"max-width: 100%;height: auto;padding: 0\"><br \/><span class=\"colour\">Adjust the settings here if necessary. For other parameters and settings in this dialog, please refer to<\/span>&nbsp;<a href=\"https:\/\/support.protasoftware.com\/portal\/en\/kb\/articles\/column-punching-check\" target=\"_blank\" rel=\"noopener noreferrer\">Column Punching Check<\/a>.<\/li>\n<li style=\"list-style-type: decimal\"><span class=\"colour\">Please enter the value of <b>Tributary Area offset<\/b> in the input field and the soil pressure will be automatic detected.&nbsp;<\/span><\/li>\n<div><span class=\"KB_New_Editor_Highlights\" style=\"margin: 10px 0px;position: relative;padding: 10px 10px 10px 40px\"><img decoding=\"async\" alt=\"Notes\" data-image=\"contentStyle\" style=\"position: absolute;left: 12px;top: 14px;width: 15px;max-width: 100%\" data-type=\"non-resize\" src=\"https:\/\/protasoftware.com\/wp-content\/uploads\/2026\/04\/prota-doc-b82cd9ecf29338042d3f117ce6b6ea0e.png\"><\/p>\n<div><b><i><span class=\"colour\">&quot;Tributary area offset&quot; <\/span><\/i><\/b><span class=\"colour\">allows you to adjust soil pressure by adjusting offset distance from the edge of the column. If you want the column to cover more it&#8217;s tributary area, you can increase the value in this input field and soil pressure will adjust accordingly.<\/span><\/div>\n<p><\/span><\/div>\n<li style=\"list-style-type: decimal\"><span class=\"colour\">Cl<\/span><span class=\"colour\">ick <\/span><b><span class=\"colour\">Calculate&nbsp;<\/span><\/b><span class=\"colour\">and result will be generated in report format.<\/span><br \/><img decoding=\"async\" data-zdeskdocselectedclass=\"best\" data-zdeskdocid=\"img_14950963216320057\" class=\"currimg docsimage\" style=\"padding: 0px;max-width: 100%;width: 649px;height: auto\" src=\"https:\/\/desk.zoho.com\/DocsDisplay?zgId=672206093&amp;mode=inline&amp;blockId=n90d745273713395b4313bcaad023e789bfed\"><\/li>\n<\/ol>\n<div><span class=\"KB_New_Editor_Highlights\" style=\"margin: 10px 0px;position: relative;padding: 10px 10px 10px 40px\"><img decoding=\"async\" alt=\"Notes\" data-image=\"contentStyle\" style=\"position: absolute;left: 12px;top: 14px;width: 15px\" data-type=\"non-resize\" src=\"https:\/\/protasoftware.com\/wp-content\/uploads\/2026\/04\/prota-doc-41a07b7204fccddbc797bfe6809c0d95.png\"><img decoding=\"async\" alt=\"Alert\" src=\"https:\/\/protasoftware.com\/wp-content\/uploads\/2026\/04\/prota-doc-bb6f77c02ef43b3826a7ffc43d15e555.png\" data-type=\"non-resize\" style=\"position: absolute;left: 12px;top: 14px;width: 15px;max-width: 100%\" data-image=\"contentStyle\"> <\/p>\n<div>\n<div><span class=\"colour\">The raft can similarly be designed by accessing the FE Foundation Analytical Model and by looking at the As(d) contours for bending.&nbsp; Refer to :&nbsp;<a href=\"https:\/\/support.protasoftware.com\/portal\/en\/kb\/articles\/finite-elements-floor-analysis-ps2022#FE_Storey_and_Foundation_Model\" target=\"_blank\" rel=\"noopener noreferrer\">FE Storey and Foundation Model<\/a><\/span><\/div>\n<\/div>\n<p><\/span><\/div>\n<div><\/div>\n<div><\/div>\n","protected":false},"excerpt":{"rendered":"<p>Raft Foundation Punching Shear Check Scope &amp; Limitation The scope of the punching shear check for raft foundation are :&nbsp; Punching shear check can be&hellip;<\/p>\n","protected":false},"author":1,"featured_media":0,"parent":0,"menu_order":0,"template":"","meta":{"_whitepaper_youtube_videos":"","_whitepaper_youtube_url":"","_whitepaper_youtube_thumbnail":"","footnotes":""},"categories":[177],"whitepaper_topic":[],"whitepaper_product":[],"whitepaper_type":[],"class_list":["post-32973","wiki","type-wiki","status-publish","hentry","category-fe-analysis-of-foundations"],"yoast_head":"<!-- This site is optimized with the Yoast SEO Premium plugin v27.9 (Yoast SEO v27.9) - https:\/\/yoast.com\/product\/yoast-seo-premium-wordpress\/ -->\n<title>Punching Shear Check For Raft Foundation - Prota Software<\/title>\n<meta name=\"description\" content=\"Raft Foundation Punching Shear Check Scope &amp; LimitationThe scope of the punching shear check for raft foundation are :&nbsp;Punching shear check can\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/protasoftware.com\/wiki\/punching-shear-check-for-raft-foundation\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Prota Software\" \/>\n<meta property=\"og:description\" content=\"Raft Foundation Punching Shear Check Scope &amp; LimitationThe scope of the punching shear check for raft foundation are :&nbsp;Punching shear check can\" \/>\n<meta property=\"og:url\" content=\"https:\/\/protasoftware.com\/wiki\/punching-shear-check-for-raft-foundation\/\" \/>\n<meta property=\"og:site_name\" content=\"Prota Software\" \/>\n<meta property=\"article:modified_time\" content=\"2026-06-19T12:37:50+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/protasoftware.com\/wp-content\/uploads\/2026\/04\/prota-doc-b8b1551b50420d6db33946497198f0fc.png\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:title\" content=\"Prota Software\" \/>\n<meta name=\"twitter:label1\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data1\" content=\"2 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/protasoftware.com\\\/wiki\\\/punching-shear-check-for-raft-foundation\\\/\",\"url\":\"https:\\\/\\\/protasoftware.com\\\/wiki\\\/punching-shear-check-for-raft-foundation\\\/\",\"name\":\"Punching Shear Check For Raft Foundation - Prota Software\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/protasoftware.com\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/protasoftware.com\\\/wiki\\\/punching-shear-check-for-raft-foundation\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/protasoftware.com\\\/wiki\\\/punching-shear-check-for-raft-foundation\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/protasoftware.com\\\/wp-content\\\/uploads\\\/2026\\\/04\\\/prota-doc-b8b1551b50420d6db33946497198f0fc.png\",\"datePublished\":\"2026-04-27T12:34:26+00:00\",\"dateModified\":\"2026-06-19T12:37:50+00:00\",\"description\":\"Raft Foundation Punching Shear Check Scope &amp; LimitationThe scope of the punching shear check for raft foundation are :&nbsp;Punching shear check can\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/protasoftware.com\\\/wiki\\\/punching-shear-check-for-raft-foundation\\\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/protasoftware.com\\\/wiki\\\/punching-shear-check-for-raft-foundation\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/protasoftware.com\\\/wiki\\\/punching-shear-check-for-raft-foundation\\\/#primaryimage\",\"url\":\"https:\\\/\\\/protasoftware.com\\\/wp-content\\\/uploads\\\/2026\\\/04\\\/prota-doc-b8b1551b50420d6db33946497198f0fc.png\",\"contentUrl\":\"https:\\\/\\\/protasoftware.com\\\/wp-content\\\/uploads\\\/2026\\\/04\\\/prota-doc-b8b1551b50420d6db33946497198f0fc.png\",\"width\":32,\"height\":32},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/protasoftware.com\\\/wiki\\\/punching-shear-check-for-raft-foundation\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/protasoftware.com\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Wiki\",\"item\":\"https:\\\/\\\/protasoftware.com\\\/wiki\\\/\"},{\"@type\":\"ListItem\",\"position\":3,\"name\":\"Punching Shear Check For Raft Foundation\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/protasoftware.com\\\/#website\",\"url\":\"https:\\\/\\\/protasoftware.com\\\/\",\"name\":\"Prota Software\",\"description\":\"\",\"publisher\":{\"@id\":\"https:\\\/\\\/protasoftware.com\\\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/protasoftware.com\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/protasoftware.com\\\/#organization\",\"name\":\"Prota Software\",\"url\":\"https:\\\/\\\/protasoftware.com\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/protasoftware.com\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/protasoftware.com\\\/wp-content\\\/uploads\\\/2026\\\/07\\\/prota-logo.png\",\"contentUrl\":\"https:\\\/\\\/protasoftware.com\\\/wp-content\\\/uploads\\\/2026\\\/07\\\/prota-logo.png\",\"width\":1200,\"height\":340,\"caption\":\"Prota Software\"},\"image\":{\"@id\":\"https:\\\/\\\/protasoftware.com\\\/#\\\/schema\\\/logo\\\/image\\\/\"}}]}<\/script>\n<!-- \/ Yoast SEO Premium plugin. -->","yoast_head_json":{"title":"Punching Shear Check For Raft Foundation - Prota Software","description":"Raft Foundation Punching Shear Check Scope &amp; LimitationThe scope of the punching shear check for raft foundation are :&nbsp;Punching shear check can","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/protasoftware.com\/wiki\/punching-shear-check-for-raft-foundation\/","og_locale":"en_US","og_type":"article","og_title":"Prota Software","og_description":"Raft Foundation Punching Shear Check Scope &amp; LimitationThe scope of the punching shear check for raft foundation are :&nbsp;Punching shear check can","og_url":"https:\/\/protasoftware.com\/wiki\/punching-shear-check-for-raft-foundation\/","og_site_name":"Prota Software","article_modified_time":"2026-06-19T12:37:50+00:00","og_image":[{"url":"https:\/\/protasoftware.com\/wp-content\/uploads\/2026\/04\/prota-doc-b8b1551b50420d6db33946497198f0fc.png","type":"","width":"","height":""}],"twitter_card":"summary_large_image","twitter_title":"Prota Software","twitter_misc":{"Est. reading time":"2 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/protasoftware.com\/wiki\/punching-shear-check-for-raft-foundation\/","url":"https:\/\/protasoftware.com\/wiki\/punching-shear-check-for-raft-foundation\/","name":"Punching Shear Check For Raft Foundation - Prota Software","isPartOf":{"@id":"https:\/\/protasoftware.com\/#website"},"primaryImageOfPage":{"@id":"https:\/\/protasoftware.com\/wiki\/punching-shear-check-for-raft-foundation\/#primaryimage"},"image":{"@id":"https:\/\/protasoftware.com\/wiki\/punching-shear-check-for-raft-foundation\/#primaryimage"},"thumbnailUrl":"https:\/\/protasoftware.com\/wp-content\/uploads\/2026\/04\/prota-doc-b8b1551b50420d6db33946497198f0fc.png","datePublished":"2026-04-27T12:34:26+00:00","dateModified":"2026-06-19T12:37:50+00:00","description":"Raft Foundation Punching Shear Check Scope &amp; LimitationThe scope of the punching shear check for raft foundation are :&nbsp;Punching shear check can","breadcrumb":{"@id":"https:\/\/protasoftware.com\/wiki\/punching-shear-check-for-raft-foundation\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/protasoftware.com\/wiki\/punching-shear-check-for-raft-foundation\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/protasoftware.com\/wiki\/punching-shear-check-for-raft-foundation\/#primaryimage","url":"https:\/\/protasoftware.com\/wp-content\/uploads\/2026\/04\/prota-doc-b8b1551b50420d6db33946497198f0fc.png","contentUrl":"https:\/\/protasoftware.com\/wp-content\/uploads\/2026\/04\/prota-doc-b8b1551b50420d6db33946497198f0fc.png","width":32,"height":32},{"@type":"BreadcrumbList","@id":"https:\/\/protasoftware.com\/wiki\/punching-shear-check-for-raft-foundation\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/protasoftware.com\/"},{"@type":"ListItem","position":2,"name":"Wiki","item":"https:\/\/protasoftware.com\/wiki\/"},{"@type":"ListItem","position":3,"name":"Punching Shear Check For Raft Foundation"}]},{"@type":"WebSite","@id":"https:\/\/protasoftware.com\/#website","url":"https:\/\/protasoftware.com\/","name":"Prota Software","description":"","publisher":{"@id":"https:\/\/protasoftware.com\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/protasoftware.com\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Organization","@id":"https:\/\/protasoftware.com\/#organization","name":"Prota Software","url":"https:\/\/protasoftware.com\/","logo":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/protasoftware.com\/#\/schema\/logo\/image\/","url":"https:\/\/protasoftware.com\/wp-content\/uploads\/2026\/07\/prota-logo.png","contentUrl":"https:\/\/protasoftware.com\/wp-content\/uploads\/2026\/07\/prota-logo.png","width":1200,"height":340,"caption":"Prota Software"},"image":{"@id":"https:\/\/protasoftware.com\/#\/schema\/logo\/image\/"}}]}},"_links":{"self":[{"href":"https:\/\/protasoftware.com\/wp-json\/wp\/v2\/wiki\/32973","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/protasoftware.com\/wp-json\/wp\/v2\/wiki"}],"about":[{"href":"https:\/\/protasoftware.com\/wp-json\/wp\/v2\/types\/wiki"}],"author":[{"embeddable":true,"href":"https:\/\/protasoftware.com\/wp-json\/wp\/v2\/users\/1"}],"version-history":[{"count":1,"href":"https:\/\/protasoftware.com\/wp-json\/wp\/v2\/wiki\/32973\/revisions"}],"predecessor-version":[{"id":36361,"href":"https:\/\/protasoftware.com\/wp-json\/wp\/v2\/wiki\/32973\/revisions\/36361"}],"wp:attachment":[{"href":"https:\/\/protasoftware.com\/wp-json\/wp\/v2\/media?parent=32973"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/protasoftware.com\/wp-json\/wp\/v2\/categories?post=32973"},{"taxonomy":"whitepaper_topic","embeddable":true,"href":"https:\/\/protasoftware.com\/wp-json\/wp\/v2\/whitepaper_topic?post=32973"},{"taxonomy":"whitepaper_product","embeddable":true,"href":"https:\/\/protasoftware.com\/wp-json\/wp\/v2\/whitepaper_product?post=32973"},{"taxonomy":"whitepaper_type","embeddable":true,"href":"https:\/\/protasoftware.com\/wp-json\/wp\/v2\/whitepaper_type?post=32973"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}